Use the buttons below to upload your .xrdml and .instprm files. Alternatively, select one of the "Use Example Files" options below to see the results from an example set of files.
Option 1: Upload Custom Files
Option 2: Use Example Files
Step 2: Statistical Inference Options
Step 3: Submit
When your data selections have been made, click the button below to run the analysis.
Running Submission... Please wait while results are computed...
Raw and Fitted Diffraction Data
Notes for User on Austenite Calculation
Normalized Intensities
Normalized Intensities per Peak Plot
Fit Values per Peak Summary Table
Calculated Theoretical Intensities per Peak
Phase Fraction
Choose Units to Display Phase Fraction Values:
Phase Fraction Values (select units)
Phase Fraction Histogram (select units)
Sources of Uncertainty (scaled by normalized intensity)
Sources of Uncertainty (per peak, scaled by normalized intensity)
Select Dataset:
Interaction Volume Table
Select Peak Index
Z Depth Histogram Plot
Incident Angle Plot
Crystallites Illuminated JSON File Creation
Variables:
Austenite Values (comma separated):
The powder size in micrometers (um).
The number of crystallites per particle.
Rocking angle of a crystal (degrees).
Optional: List of texture correction values (MRD). Not currently supported, add after downloading
Ferrite Values (comma separated):
The powder size in micrometers (um).
The number of crystallites per particle.
Rocking angle of a crystal (degrees).
Optional: List of texture correction values (MRD). Not currently supported, add after downloading
beam_shape: Shape of the aperature of the incident x-ray. Options are "square" and "circle"
beam_size: Size of the aperature (mm). Diameter for circular beams, edge length for square beams. Currently does not account for beam divergence.
raster_x: Oscillation length in the diffractometer x direction (mm). If the sample is oscillated at a rate signficantly greater than the scan increment rate, the raster area defines the illuminated volume instead of the beam_size.
raster_y: Oscillation length in the diffractometer y direction (mm). If the sample is oscillated at a rate signficantly greater than the scan increment rate, the raster area defines the illuminated volume instead of the beam_size.
sample_displacement: distance (um) the sample surface is displaced from the focus center of the x-ray system.
L: Sample to x-ray source distance (mm). Currently assumes that the sample to detector distance is equivalent.
W_F: Apparent width of the x-ray tube focus (mm). As these are often described as the slit width, they should be the same or similar to the the beam_size dimension.
H_F: Height of the x-ray tube focus (mm). As these are often described as the slit height, they should be the same or similar to the the beam_size dimension.
H_R: The smallest of either the height of the receiving slit or detector window (mm). For 2D detectors, H_R can often be calculated from the gamma term via the equation H_R=gamma*L.
Instrument Parameter File Creation
Instrument file creation not currently supported
Click the button below to download the results once the analysis has been completed. The results will then
be downloaded as a .zip file in the form several Python pickle files.